D-24, MIDC-Ambad, Nasik – 422010, MH, India

Condition Monitoring Of Transformer Oil

Testing and analysis of the transformer oil gives us the assessment of oil as well as transformer condition in it’s running state, enabling us to take better preventive actions and avoid failures / breakdowns. We are India’s leading NABL accredited private laboratory in transformer oil testing as per IEC / IS / ASTM. We also provide emergency on site transformer oil testing services with our NABL accredited Mobile Lab

Transformer Mineral Insulating Oil Condition

Oil and other insulating liquids suffer from electrical and mechanical stresses while a transformer is in operation. In addition there are contaminations caused due to chemical interactions with windings and other solid insulations, catalyzed by high operating temperature. As a result the original chemical properties of transformer oil changes gradually, rendering it ineffective for its intended purpose after many years.

Hence this oil has to be periodically tested to ascertain its basic electrical properties, and make sure it is suitable for further use or initiate necessary actions like filtration/regeneration. Transformer Oil is not only subject to its own degradation, but is also a carrier of gasses emanated during arcing or flashovers between paper and winding insulations.

Transformer Oil Testing and Analysis provides important information regarding any such incipient faults, without the need to pull down the equipment from its running condition. We are India’s leading private laboratory for Transformer Oil testing as per IEC 17025:2000

Physical Parameters

  • Appearance
  • Interfacial Tension
  • Flash Point
  • Pour Point
  • Density
  • Kinematic Viscosity

Chemical Parameters

  • Water Content
  • Total Acid Number / Neutralization Value
  • Sediments And Sludge

Electrical Parameters

  • Breakdown Voltage / Dielectric Strength
  • Specific Resistance / Resistivity
  • Dielectric Dissipation Factor / Tan Delta

Transformer Internal Condition

  • Dissolved Gas Analysis ( DGA )

Transformer Insulating Paper Condition

  • Furanic Compound Analysis ( Furans )

Other Special Test As Per Customer Requirement

Testing Packages as per IS/IEC/ASTM Standards

Transformer Oil Testing Advanced Laboratory ( TOTAL )

Power Electronical NABL Accredited Stationary Oil Testing Lab

At Power Electronical’s Transformer Oil Testing Advanced Laboratory (TOTAL) we are committed to adhere and practice international systems for quality management and Oil Testing & Analysis. We have valid accreditations for ISO/IEC 17025:2005 from NABL and ISO9000:2000. Both the accreditations allows our customers to be able to compare and use the test readings and our analysis to a scale comparable with National test laboratories. It is also a proof of our unswerving commitment to highest levels of quality standards for Oil testing.

Transformer Condition Monitoring Services

Oil Testing is only half the work done. Without correct and accurate analysis, it serves no worthwhile purpose. Our engineers and laboratory staff are well equipped with knowledge and experience to be able to analyze the results and predict any kind of rapid degradation of Oil parameters, or advise residual life expectancy or fault interpretation. We follow it up with site visit and testing of other parameters of your equipment, to confirm the assessment, and help the customer take preventive and corrective measures well within time. A maintenance contract signed with us for all your critical HV/EHV equipment gives you complete peace of mind, because we look after them 24X7 thereafter, including scheduled and emergency visits.

Convenience with TOTAL association

  • Oil test results provided within 3 working days from sample receipt
  • Logistic control and handling may be done by TOTAL, on customer’s request
  • All tests done under controlled temperature and humidity, to maintain test integrity
  • All testing data records maintained for a period of 6 years
  • Statistical trending & analysis, on request
  • Experienced persons handling test operations, on continual basis since past 5 years
  • Single point communication window established for all customers

NABL accredited Mobile Oil Testing Laboratory

24×7 Emergency Onsite Oil Testing Service

Transformer is a very vital as well as critical equipment of the entire power grid. Thus sometimes we need to take decisions instantly without having to wait for the typical period required in getting test results. For such situations we have the solution which not only provide instantaneous results on site but also provide accurate and expert assessment. Our NABL accredited transformer oil testing lab is able to visit your plant fulfilling all your requirements of oil testing and analysis on site.

  • Equipped with well convergent technicians who are specially trained for Oil sampling as per IS Standard
  • Manned with expert engineers to do the Oil Testing as per IS Standards and analyze the results
  • Customer is able to monitor the process at their own premises
  • Repeatability of test results possible
  • DGA testing facility with auto sampler method (Method C) which is worldwide approved and acceptable (Without human error).
  • Normally you can get Oil Testing Reports after 15 to 30 days in conventional process, but here you can get the results on site itself.
  • We are maintaining pervious Oil Testing data in our data base for our regular customers, so in this way you are able to get Trend Analysis on site itself.

We provide RLA / Diagnostic Testing Of Transformer as well for complete one stop solution for our customers

Fill out the form below and we will contact you as soon as possible!