PE-AORDF-1 is a fully automatic oil resistivity & tan-delta tester. It is an integrated unit, consisting of heater unit and measuring bridge. The stainless steel oil cell is to be mounted inside the HF induction heater cubicle, and HV is engaged to it automatically. Measuring bridge consists of AC/DC high voltage supply, tera-ohm meter, and precision electronic bridges to measure and derive readings for :
Resistance
Resistivity
Capacitance
Power Factor
Tan-delta
Watt-loss
Dielectric Constant
Temperature
Pre-programmed international test methods compliant to:
ASTM-D924-04, ASTM-D1169, IEC-60247, IEC-61620, IS-6262/6103, NBR 12133, VDE-0380-2, BS-5737
Power Supply- Single Phase 220V AC 50 Hz ± 10%
Input pin type- Round 3-pin (L, N, E). European, Australian, US pin types available on request
Measuring Bridge VA- max 500VA
Heater VA- max 500VA
For Dielectric Constant & Tan-Delta- 60V to 2000V AC (in steps of 1V)
For DC Resistivity- 100V to 2000V DC (in steps of 1V)
Accuracy of Voltage setting- + (1% of set value + 10V)
Storage Temp- minus 20°C to +60°C
Operating Temp- minus 10°C to +50°C
Humidity- < 90% non-condensing
Temperature Range- ambient to 110°C, resolution 0.1°C
Temperature error- 0.5 °C (max)
Time to 100°C- < 20 mins
Tan Delta range- 0 to 4
Tan Delta resolution- 0.000001 (10 -6)
Tan Delta Accuracy- 1 % of reading + 0.00005
Capacitance range- 15.0 pF to 1000 pF
Capacitance resolution- 0.1 pF
Capacitance Accuracy- 0.1% of reading + 0.5pF
Dielectric Constant range- 1 to 20 when using a typical test cell (C ~ 50-60pF)
Dielectric Constant resolution- 0.001
Dielectric Constant Accuracy- + 0.1 %
Resistance Range- 1 MΩ to 10 TΩ (not calibrated above 10TΩ)
Resistance Resolution- 4 digits
Resistance Accuracy- 5% of reading over entire range, 10% beyond 1TΩ
Resistivity Range- 500 MΩ cm to 10000 TΩ cm (for type C empty – 55pF)
Resistivity Resolution- 4 digits
Resistivity Accuracy- 5% of reading over entire range, 10% for > 500TΩcm
Complete automatic test procedure. Once test voltage is selected, it applies excitation to the 3-terminal Oil cell, measures R, C, DF, F, V, and then displays and prints the results on integrated printer
High Accuracy, Best resolution in its class
Pure Sine test operation for AC measurements and <0.1% ripple for DC measurements>
Heater interfaced with main unit for temperature set, control and display
Multiple temperature set values programmable
Programmable cell constant for Resistivity and Dielectric Constant
SF6 Gas Capacitor integrated inside for standard reference
7″ color TFT display with touch screen with wireless keyboard for user convenience
Integrated Programmable AC & DC test voltages
Thermal printer for immediate printing
Pre-programmed 9 test sequences, and user-programmable 10 test sequences
USB 2.0 interface for PC
PC software for control and display of test results
On-site calibration possible for yearly schedule
Optional Bluetooth / RS485 / RF interface with user definable config, for Automated Laboratory setup
Testing various electrical properties and specifications of insulating dielectric oils such as:
Resistance
Resistivity
Capacitance
Power Factor
Tan-delta
Watt-loss
Dielectric Constant
Temperature
Heater unit- 1 no
Closed cup SS Oil cell- 1 no
Printer roll- 1 no (already loaded), plus 1 spare roll
Connecting AC mains cable- 1 no
Connection test leads- 1 set
User manual (Video CD)- 1 no
Test certificate- 1 no
Warranty Certificate- 1no (Standard warranty 1 yr)
Fill out the form below to download datasheet & we will contact you soon
Fill out the form below and we will contact you as soon as possible!