NABL Accredited Transformer Oil Testing Laboratory (TOTL)
We are India’s leading private laboratory for Transformer Oil testing as per IEC 17025:2000.. Based in the same premises as the HQ office, it allows for constant supervision and monitoring of test methods and testing procedures. The NABL accreditation for this test laboratory is the icing on the cake, and allows us to certify our test results with authority that very few laboratories across India can match. Add the low turnaround time for sample testing, the precise & accurate results, and the secured test database; the high demand from our customers is making us almost approach the end of spare capacity. Hence we are planning to set up a couple more of regional laboratories across India and Mid-East.
We do the following standard tests at our laboratory
Transformer Oil Testing
Shortly, we will be adding Furanic Compound Analysis and PCB testing also!
All these tests are done as per relevant IS, IEC or ASTM standard, as is applicable, or as is demanded by our customers complying to following test procedures
Sr. | Tests | IEC | ASTM | IS |
1 | Color & Appearance | ISO 2049 | D-1500 | IS 335 |
2 | Breakdown Voltage | IEC 60156 | D-877 | IS 6792 |
3 | Water Content | IEC 60814 | D-1533 B | IS 13567 |
4 | Acidity (Neutralization Value) | IEC 62021 | D-974 | IS 1448 [P-2] |
5 | Dielectric Dissipation Factor | IEC 60247 | D-924 | IS 6262 |
6 | Resistivity | IS 6103 | ||
7 | Sediments & Sludge | IEC 61125 | D-1524 | IS 1866 |
8 | Interfacial Tension | ISO 6295 | D-971 | IS 6104 |
9 | Flash Point | IEC 2719 | D-92 | IS 1448 |
10 | Pour Point | ISO 3016 | D-971 | IS 1448 |
11 | Density | IEC 60814 | D-1298 | IS 1448 |
12 | Kinematic Viscosity | ISO 3104 | D-445 | IS 1448 [P-25] |
13 | Dissolved Gas Analysis | NA | D-3612 | IS 9434 |
14 | Polychlorinated biphenyls (PCB's) ** | IEC 61619 | D-4059 | --- |
15 | Furan Analysis ** | IEC 61198 | D-5837 | --- |
We also do on-site -
Testing of Power Transformers
Testing of HT Motors & Generators
Testing of Bushings, CTs, CVT, Winding etc
Testing & Commissioning of EHV substations (up to 400kV)
Write to us to know more about how we can help you do your work better
Very soon we plan to add Transformer Oil Purification to our service portfolio, and keep on seeing this space for more information on it.