HV Breakdown Testers

The breakdown voltage test is an important test to determine the withstanding capacity of any insulating oil, liquid or solid. There is a degradation of transformer oils, varnishes, winding insulation etc, and it is necessary to test them preiodically or before using them in assemblies. Power Electronical offers Oil Breakdown Testers and High Voltage breakdown sources for testing other materials

  • PE-AOBDV-3    Automatic Oil Breakdown Voltage Tester

     

    Automatic Oil Breakdown Voltage Tester (Oil BDV)

    PE-AOBDV  Automatic Oil Breakdown Voltage Testeris a highly precise instrument, which can be applied to measure either the breakdown voltage or also check the withstanding voltage for a predefined time. Usual available automatic test sets only perform the former function, but PE-AOBDV can do both. PE-AOBDV can measure the breakdown voltage repetitively and computes an average reading, for a proper decision making. PE-AOBDV consists of an integrated Oil Cup, HV AC power source

     

     

     

    Features

    -  0-80kV or 0-100kV smooth operation, 5mA trip current

    -  Complete Automatic operation

    -  Non-contact magnetic stirring

    -  Programmable Stir, Hold, and Intermediate Stand times

    -  Programmable voltage ramp rate

    -  Repetitive test sequence and average readings

    -  Digital display output

    -  Integrated thermal Printer

    -  Internal memory for data storage and recall

    -  Included IS 6792, IEC 60156 and GB507-86 test sequences

    -  Programmable test sequences as per requirement

     

                                                             click here to get a PDF copy of the complete data-sheet